High and low voltage switchgear

High and low voltage switchgear

Description

The high and low voltage switchgear says that it is the machine equipment that connects the pressure or the bottom voltage cable. Usually, the power supply bureau and the substation all use the high voltage cabinet, and then the transformer drops the blood pressure to the low voltage switch cabinet, and the low voltage switch cabinet goes to each. Power distribution cabinets, just to say that some of the maintenance components such as power switch is assembled into an integrated electrical equipment. The high and low voltage switchgear is this kind of electric equipment. The external line is advanced to the main control chip power switch in the cabinet, and then enters the sub-control power switch, and each branch must be set according to it. Such as instrument panel, automatic control, motor magnetic field power switch, various contactors, etc.

  • Product details page 1

  • Product details page 2

  • Additional product information

  • product manual

The high and low voltage switchgear says that it is the machine equipment that connects the pressure or the bottom voltage cable. Usually, the power supply bureau and the substation all use the high voltage cabinet, and then the transformer drops the blood pressure to the low voltage switch cabinet, and the low voltage switch cabinet goes to each. Power distribution cabinets, just to say that some of the maintenance components such as power switch is assembled into an integrated electrical equipment.

The high and low voltage switchgear is this kind of electric equipment. The external line is advanced to the main control chip power switch in the cabinet, and then enters the sub-control power switch, and each branch must be set according to it. Such as instrument panel, automatic control, motor magnetic field power switch, various contactors, etc., some also set pressure chamber and bottom pressure chamber high voltage switch cabinet, under high voltage bus, such as power station, etc. To ensure low-cycle load shedding of critical machinery and equipment. 1. The bottom pressure extraction type high voltage switch cabinet, communication and exchange low voltage power distribution cabinet, metal material armored cable shift open type high voltage switch cabinet, bottom pressure fixed non-moving separated high voltage switch cabinet, high voltage capacitor cabinet, high voltage cabinet.

Safety operation rules for safety production technology of high and low voltage switchgear

1. In all work and some of the induction-inducing disks, the maintenance machine equipment and the operating machinery equipment should be separated by a prominent mark.

2. Re-winding of voltage transformers and voltage transformers requires permanent, reliable grounding protection.

3. When working on the secondary circuit of the operating voltage transformer, the following safety precautions should be taken:

3.1 It is forbidden to break the current quantity control loop.

3.2 In order to reliably short-circuit the voltage transformer to the electromagnetic coil again, it is necessary to apply the short-circuit fault piece and the short-circuit line. It is strictly forbidden to apply the power line coiling.

3.3 It is strictly forbidden to carry out all work on the control circuit and transmission line between the voltage transformer and the short-circuit faulty terminal.

4. When working on the secondary circuit of the voltage transformer in operation, the following safety precautions should be taken:

4.1 Harsh to avoid short circuit faults or grounding devices.

4.2 Insulation tools should be used, and gloves with insulation should be worn. If necessary, stop using the relevant relay protection device before working.

4.3 When connecting to a temporary load, be sure to have a dedicated power switch and circuit breaker.

4.4 In the secondary loop plug-in experiment, in order to avoid the reverse transformation of the side by one side, in addition to breaking the secondary loop, it is also advisable to use the next circuit breaker.

4.5 Before the secondary loop plug-in or AC withstand voltage test, the duty officer and relevant staff should be notified, and the person should be sent to the scene to check the control loop, and it is determined that no one can work in the back and then can be pressurized.

4.6 Check the work of the power supply maintenance and re-control loop, and all the switching operations are prohibited without the approval of the staff.